Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 23.540
Filtrar
1.
Ann Card Anaesth ; 27(1): 51-52, 2024 Jan 01.
Artículo en Inglés | MEDLINE | ID: mdl-38722121

RESUMEN

ABSTRACT: The quadricuspid aortic valve is a rare congenital anomaly, usually associated with aortic regurgitation requiring surgical intervention. It may be associated with other congenital anomalies such as coronary anomalies, patent ductus arteriosus, ventricular septal defect, pulmonary stenosis, and subaortic stenosis. The diagnosis is generally established by either transthoracic or transesophageal echocardiography. Herein, we report a case of a 52-year-old woman who was diagnosed to have quadricuspid aortic valve by intraoperative transesophageal echocardiography.


Asunto(s)
Válvula Aórtica , Ecocardiografía Transesofágica , Humanos , Femenino , Válvula Aórtica/anomalías , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Persona de Mediana Edad , Ecocardiografía Transesofágica/métodos , Insuficiencia de la Válvula Aórtica/cirugía , Insuficiencia de la Válvula Aórtica/diagnóstico por imagen , Cardiopatías Congénitas/diagnóstico por imagen , Cardiopatías Congénitas/cirugía
2.
Ann Card Anaesth ; 27(1): 53-57, 2024 Jan 01.
Artículo en Inglés | MEDLINE | ID: mdl-38722122

RESUMEN

ABSTRACT: Aortic valve (AV) repair is the desired surgical treatment option for young patients with aortic regurgitation (AR). It is considered as a class I indication for the surgical treatment of severeAR. The success of an AV repair depends on the detailed intraoperative transesophageal echocardiographic (TEE) examination which should fulfil the information required by the surgeon. The objective of this echo round is to describe the role of intraoperative TEE in systematic evaluation of the AV, before and after repair.


Asunto(s)
Insuficiencia de la Válvula Aórtica , Válvula Aórtica , Ecocardiografía Transesofágica , Monitoreo Intraoperatorio , Humanos , Ecocardiografía Transesofágica/métodos , Insuficiencia de la Válvula Aórtica/cirugía , Insuficiencia de la Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Válvula Aórtica/diagnóstico por imagen , Niño , Monitoreo Intraoperatorio/métodos
3.
EuroIntervention ; 20(9): 579-590, 2024 May 10.
Artículo en Inglés | MEDLINE | ID: mdl-38726714

RESUMEN

BACKGROUND: Data on the performance of the latest-generation SAPIEN 3 Ultra RESILIA (S3UR) valve in patients who undergo transcatheter aortic valve replacement (TAVR) are scarce. AIMS: We aimed to assess the clinical outcomes, including valve performance, of the S3UR. METHODS: Registry data of 618 consecutive patients with S3UR and of a historical pooled cohort of 8,750 patients who had a SAPIEN 3 (S3) valve and underwent TAVR were collected. The clinical outcomes and haemodynamics, including patient-prosthesis mismatch (PPM), were compared between the 2 groups and in a propensity-matched cohort. RESULTS: The incidence of in-hospital death, vascular complications, and new pacemaker implantation was similar between the S3UR and the S3 groups (allp>0.05). However, both groups showed significant differences in the degrees of paravalvular leakage (PVL) (none-trivial: 87.0% vs 78.5%, mild: 12.5% vs 20.5%, ≥moderate: 0.5% vs 1.1%; p<0.001) and the incidence of PPM (none: 94.3% vs 85.1%, moderate: 5.2% vs 12.8%, severe: 0.5% vs 2.0%; p<0.001). The prevalence of a mean pressure gradient ≥20 mmHg was significantly lower in the S3UR group (1.6% vs 6.2%; p<0.001). Better haemodynamics were observed with the smaller 20 mm and 23 mm S3UR valves. The results were consistent in a matched cohort of patients with S3UR and with S3 (n=618 patients/group). CONCLUSIONS: The S3UR has equivalent procedural complications to the S3 but with lower rates of PVL and significantly better valve performance. The better valve performance of the S3UR, particularly in smaller valve sizes, overcomes the remaining issue of balloon-expandable valves after TAVR.


Asunto(s)
Estenosis de la Válvula Aórtica , Válvula Aórtica , Prótesis Valvulares Cardíacas , Sistema de Registros , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/instrumentación , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Femenino , Masculino , Anciano de 80 o más Años , Anciano , Estenosis de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/fisiopatología , Resultado del Tratamiento , Válvula Aórtica/cirugía , Válvula Aórtica/fisiopatología , Válvula Aórtica/diagnóstico por imagen , Diseño de Prótesis , Hemodinámica , Complicaciones Posoperatorias/epidemiología , Complicaciones Posoperatorias/etiología , Mortalidad Hospitalaria
4.
EuroIntervention ; 20(9): 536-550, 2024 May 10.
Artículo en Inglés | MEDLINE | ID: mdl-38726720

RESUMEN

The identification and management of patients at high bleeding risk (HBR) undergoing transcatheter aortic valve implantation (TAVI) are of major importance, but the lack of standardised definitions is challenging for trial design, data interpretation, and clinical decision-making. The Valve Academic Research Consortium for High Bleeding Risk (VARC-HBR) is a collaboration among leading research organisations, regulatory authorities, and physician-scientists from Europe, the USA, and Asia, with a major focus on TAVI-related bleeding. VARC-HBR is an initiative of the CERC (Cardiovascular European Research Center), aiming to develop a consensus definition of TAVI patients at HBR, based on a systematic review of the available evidence, to provide consistency for future clinical trials, clinical decision-making, and regulatory review. This document represents the first pragmatic approach to a consistent definition of HBR evaluating the safety and effectiveness of procedures, devices and drug regimens for patients undergoing TAVI..


Asunto(s)
Consenso , Hemorragia , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Factores de Riesgo , Hemorragia/etiología , Medición de Riesgo , Estenosis de la Válvula Aórtica/cirugía , Válvula Aórtica/cirugía
5.
Laeknabladid ; 110(5): 247-253, 2024 May.
Artículo en Islandés | MEDLINE | ID: mdl-38713559

RESUMEN

INTRODUCTION: One of the most serious complications of surgical aortic valve replacement (SAVR) is stroke that can result in increased rates of complications, morbidity and mortality postoperatively. The aim of this study was to investigate incidence, risk factors and short-term outcome in a well defined cohort of SAVR-patients. MATERIALS AND METHOD: A retrospective study on 740 consecutive aortic stenosis patients who underwent SAVR in Iceland 2002-2019. Patients with stroke were compared with non-stroke patients; including preoperative risk factors of cardiovascular disease, echocardiogram-results, rate of early postoperative complications other than stroke and 30 day mortality. RESULTS: Mean age was 71 yrs (34% females) with 57% of the patients receiving stented bioprosthesis, 31% a stentless Freestyle®-valve and 12% a mechanical valve. Mean EuroSCORE-II was 3.6, with a maximum preop-gradient of 70 mmHg and an estimated valvular area of 0.73 cm2. Thirteen (1.8%) patients were diagnosed with stroke where hemiplegia (n=9), loss of consciousness (n=3) and/or aphasia (n=4) were the most common presenting symptoms. In 70% of cases the neurological symptoms resolved or disappeared in the first weeks and months after surgery. Only one patient out of 13 died within 30-days (7.7%). Stroke-patients had significantly lower BMI than non-stroke patients, but other risk factors of cardiovascular diseases, intraoperative factors or the rate of other severe postoperative complications than stroke were similar between groups. Total length of stay was 14 days vs. 10 days median, including 2 vs. 1 days in the ICU, in the stroke and non-stroke-groups, respectively. CONCLUSIONS: The rate of stroke after SAVR was low (1.8%) and in line with other similar studies. Although a severe complication, most patients with perioperative stroke survived 30 days postoperatively and in majority of cases neurological symptoms recovered.


Asunto(s)
Estenosis de la Válvula Aórtica , Válvula Aórtica , Implantación de Prótesis de Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Accidente Cerebrovascular , Humanos , Femenino , Estenosis de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/mortalidad , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Masculino , Anciano , Factores de Riesgo , Estudios Retrospectivos , Islandia/epidemiología , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Implantación de Prótesis de Válvulas Cardíacas/mortalidad , Implantación de Prótesis de Válvulas Cardíacas/instrumentación , Accidente Cerebrovascular/epidemiología , Accidente Cerebrovascular/mortalidad , Accidente Cerebrovascular/etiología , Incidencia , Factores de Tiempo , Resultado del Tratamiento , Válvula Aórtica/cirugía , Válvula Aórtica/diagnóstico por imagen , Medición de Riesgo , Anciano de 80 o más Años , Persona de Mediana Edad
6.
Sci Rep ; 14(1): 10409, 2024 05 06.
Artículo en Inglés | MEDLINE | ID: mdl-38710782

RESUMEN

In transcatheter aortic valve implantation (TAVI), final device position may be affected by device interaction with the whole aortic landing zone (LZ) extending to ascending aorta. We investigated the impact of aortic LZ curvature and angulation on TAVI implantation depth, comparing short-frame balloon-expanding (BE) and long-frame self-expanding (SE) devices. Patients (n = 202) treated with BE or SE devices were matched based on one-to-one propensity score. Primary endpoint was the mismatch between the intended (HPre) and the final (HPost) implantation depth. LZ curvature and angulation were calculated based on the aortic centerline trajectory available from pre-TAVI computed tomography. Total LZ curvature ( k L Z , t o t ) and LZ angulation distal to aortic annulus ( α L Z , D i s t a l ) were greater in the SE compared to the BE group (P < 0.001 for both). In the BE group, HPost was significantly higher than HPre at both cusps (P < 0.001). In the SE group, HPost was significantly deeper than HPre only at the left coronary cusp (P = 0.013). At multivariate analysis, α L Z , D i s t a l was the only independent predictor (OR = 1.11, P = 0.002) of deeper final implantation depth with a cut-off value of 17.8°. Aortic LZ curvature and angulation significantly affected final TAVI implantation depth, especially in high stent-frame SE devices reporting, upon complete release, deeper implantation depth with respect to the intended one.


Asunto(s)
Estenosis de la Válvula Aórtica , Válvula Aórtica , Reemplazo de la Válvula Aórtica Transcatéter , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Humanos , Masculino , Femenino , Anciano de 80 o más Años , Anciano , Válvula Aórtica/cirugía , Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Tomografía Computarizada por Rayos X , Aorta/diagnóstico por imagen , Aorta/cirugía , Resultado del Tratamiento , Prótesis Valvulares Cardíacas , Estudios Retrospectivos
7.
Port J Card Thorac Vasc Surg ; 31(1): 12-16, 2024 May 13.
Artículo en Inglés | MEDLINE | ID: mdl-38743522

RESUMEN

There has been a worldwide rapid adoption of transcatheter aortic valve replacement (TAVR) as an alternative to surgical aortic valve replacement (SAVR) for patients with severe aortic stenosis. Currently, more TAVR explants with SAVRs are performed than TAVR-in TAV. TAVR explantation is a technically hazardous procedure mainly due to significant aortic neo-endothelialization which incorporates the TAVR valve. Surgical techniques for TAVR explantation are not well established and surgeon experience at present is limited. In this manuscript, we describe our technique for surgical explantation of transcatheter aortic bioprosthesis. Familiarity with the procedure and its clinical implications is essential for all cardiac surgeons.


Asunto(s)
Estenosis de la Válvula Aórtica , Bioprótesis , Remoción de Dispositivos , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/instrumentación , Estenosis de la Válvula Aórtica/cirugía , Bioprótesis/efectos adversos , Remoción de Dispositivos/métodos , Prótesis Valvulares Cardíacas/efectos adversos , Válvula Aórtica/cirugía , Válvula Aórtica/patología
8.
Europace ; 26(5)2024 May 02.
Artículo en Inglés | MEDLINE | ID: mdl-38691562

RESUMEN

AIMS: We examined whether thickness of the basal muscular interventricular septum (IVS), as measured by pre-procedural computed tomography (CT), could be used to identify the risk of conduction disturbances following transcatheter aortic valve replacement (TAVR). The IVS is a pivotal region of the electrical conduction system of the heart where the atrioventricular conduction axis is located. METHODS AND RESULTS: Included were 78 patients with severe aortic stenosis who underwent CT imaging prior to TAVR. The thickness of muscular IVS was measured in the coronal view, in systolic phases, at 1, 2, 5, and 10 mm below the membranous septum (MS). The primary endpoint was a composite of conduction disturbance following TAVR. Conduction disturbances occurred in 24 out of 78 patients (30.8%). Those with conduction disturbances were significantly more likely to have a thinner IVS than those without conduction disturbances at every measured IVS level (2.98 ± 0.52 mm vs. 3.38 ± 0.52 mm, 4.10 ± 1.02 mm vs. 4.65 ± 0.78 mm, 6.11 ± 1.12 mm vs. 6.88 ± 1.03 mm, and 9.72 ± 1.95 mm vs. 10.70 ± 1.55 mm for 1, 2, 5 and 10 mm below MS, respectively, P < 0.05 for all). Multivariable logistic regression analysis showed that pre-procedural IVS thickness (<4 mm at 2 mm below the MS) was a significant independent predictor of post-procedural conduction disturbance (adjOR 7.387, 95% CI: 2.003-27.244, P = 0.003). CONCLUSION: Pre-procedural CT assessment of basal IVS thickness is a novel predictive marker for the risk of conduction disturbances following TAVR. The IVS thickness potentially acts as an anatomical barrier protecting the underlying conduction system from mechanical compression during TAVR.


Asunto(s)
Estenosis de la Válvula Aórtica , Reemplazo de la Válvula Aórtica Transcatéter , Tabique Interventricular , Humanos , Masculino , Femenino , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Estenosis de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Tabique Interventricular/diagnóstico por imagen , Anciano de 80 o más Años , Factores de Riesgo , Anciano , Arritmias Cardíacas/etiología , Arritmias Cardíacas/fisiopatología , Arritmias Cardíacas/diagnóstico por imagen , Sistema de Conducción Cardíaco/fisiopatología , Sistema de Conducción Cardíaco/diagnóstico por imagen , Resultado del Tratamiento , Valor Predictivo de las Pruebas , Medición de Riesgo , Índice de Severidad de la Enfermedad , Estudios Retrospectivos , Válvula Aórtica/cirugía , Válvula Aórtica/diagnóstico por imagen , Tomografía Computarizada Multidetector , Tomografía Computarizada por Rayos X , Potenciales de Acción
9.
Eur J Cardiothorac Surg ; 65(5)2024 May 03.
Artículo en Inglés | MEDLINE | ID: mdl-38710669

RESUMEN

OBJECTIVES: The objective of this analysis was to assess the normal haemodynamic performance of contemporary surgical aortic valves at 1 year postimplant in patients undergoing surgical aortic valve replacement for significant valvular dysfunction. By pooling data from 4 multicentre studies, this study will contribute to a better understanding of the effectiveness of surgical aortic valve replacement procedures, aiding clinicians and researchers in making informed decisions regarding valve selection and patient management. METHODS: Echocardiograms were assessed by a single core laboratory. Effective orifice area, dimensionless velocity index, mean aortic gradient, peak aortic velocity and stroke volume were evaluated. RESULTS: The cohort included 2958 patients. Baseline age in the studies ranged from 70.1 ± 9.0 to 83.3 ± 6.4 years, and Society of Thoracic Surgeons risk of mortality was 1.9 ± 0.7 to 7.5 ± 3.4%. Twenty patients who had received a valve model implanted in fewer than 10 cases were excluded. Ten valve models (all tissue valves; n = 2938 patients) were analysed. At 1 year, population mean effective orifice area ranged from 1.46 ± 0.34 to 2.12 ± 0.59 cm2, and dimensionless velocity index, from 0.39 ± 0.07 to 0.56 ± 0.15. The mean gradient ranged from 8.6 ± 3.4 to 16.1 ± 6.2 mmHg with peak aortic velocity of 1.96 ± 0.39 to 2.65 ± 0.47 m/s. Stroke volume was 75.3 ± 19.6 to 89.8 ± 24.3 ml. CONCLUSIONS: This pooled cohort is the largest to date of contemporary surgical aortic valves with echocardiograms analysed by a single core lab. Overall haemodynamic performance at 1 year ranged from good to excellent. These data can serve as a benchmark for other studies and may be useful to evaluate the performance of bioprosthetic surgical valves over time. CLINICAL TRIAL REGISTRATION NUMBER: NCT02088554, NCT02701283, NCT01586910 and NCT01531374.


Asunto(s)
Válvula Aórtica , Bioprótesis , Implantación de Prótesis de Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Hemodinámica , Humanos , Hemodinámica/fisiología , Válvula Aórtica/cirugía , Válvula Aórtica/diagnóstico por imagen , Anciano , Femenino , Masculino , Anciano de 80 o más Años , Implantación de Prótesis de Válvulas Cardíacas/métodos , Ecocardiografía , Persona de Mediana Edad , Diseño de Prótesis
10.
Sci Rep ; 14(1): 10902, 2024 05 13.
Artículo en Inglés | MEDLINE | ID: mdl-38740898

RESUMEN

Calcification of the aortic valve (CAVDS) is a major cause of aortic stenosis (AS) leading to loss of valve function which requires the substitution by surgical aortic valve replacement (SAVR) or transcatheter aortic valve intervention (TAVI). These procedures are associated with high post-intervention mortality, then the corresponding risk assessment is relevant from a clinical standpoint. This study compares the traditional Cox Proportional Hazard (CPH) against Machine Learning (ML) based methods, such as Deep Learning Survival (DeepSurv) and Random Survival Forest (RSF), to identify variables able to estimate the risk of death one year after the intervention, in patients undergoing either to SAVR or TAVI. We found that with all three approaches the combination of six variables, named albumin, age, BMI, glucose, hypertension, and clonal hemopoiesis of indeterminate potential (CHIP), allows for predicting mortality with a c-index of approximately 80 % . Importantly, we found that the ML models have a better prediction capability, making them as effective for statistical analysis in medicine as most state-of-the-art approaches, with the additional advantage that they may expose non-linear relationships. This study aims to improve the early identification of patients at higher risk of death, who could then benefit from a more appropriate therapeutic intervention.


Asunto(s)
Estenosis de la Válvula Aórtica , Válvula Aórtica , Calcinosis , Aprendizaje Profundo , Humanos , Válvula Aórtica/cirugía , Válvula Aórtica/patología , Calcinosis/cirugía , Calcinosis/mortalidad , Femenino , Masculino , Anciano , Estenosis de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/mortalidad , Reemplazo de la Válvula Aórtica Transcatéter/mortalidad , Anciano de 80 o más Años , Análisis de Supervivencia , Factores de Riesgo , Modelos de Riesgos Proporcionales , Medición de Riesgo/métodos , Implantación de Prótesis de Válvulas Cardíacas/mortalidad , Implantación de Prótesis de Válvulas Cardíacas/métodos , Persona de Mediana Edad
13.
J Cardiothorac Surg ; 19(1): 279, 2024 May 07.
Artículo en Inglés | MEDLINE | ID: mdl-38715032

RESUMEN

OBJECTIVE: Reports on long-term outcomes of surgical aortic valve replacement (AVR) for patients aged < 60 years are scarce in Japan. Hence, we aimed to evaluate these outcomes in patients aged < 60 years. METHODS: Between March 2000 and December 2020, 1477 patients underwent aortic valve replacement. In total, 170 patients aged < 60 years who underwent aortic valve replacement were recruited. Patients aged < 18 years were excluded. Patient data collected from the operative records and follow-up assessments were reviewed. RESULTS: The mean age was 49 ± 9 years, and 64.1% of patients were male. One-hundred-and-fifty-two patients (89.4%) underwent aortic valve replacement with a mechanical valve and 18 (10.6%) with a bioprosthetic valve. The mean follow-up period was 8.1 ± 5.5 years. No operative mortality occurred, and in-hospital mortality occurred in one patient (0.6%). Ten late deaths occurred, with seven cardiac-related deaths. The overall survival rate was 95.4 ± 1.7%, 93.9 ± 2.3%, 90.6 ± 3.9%, and 73.2 ± 11.8% at 5, 10, 15, and 20 years, respectively. Freedom from major bleeding was 96.4 ± 1.6% at 5, 10, and 15 years, and 89.0 ± 7.3% at 20 years. Freedom from thromboembolic events was 98.7 ± 1.3%, 97.3 ± 1.9%, 90.5 ± 4.5%, and 79.0 ± 11.3% at 5, 10, 15, and 20 years, respectively. Freedom from valve-related reoperation was 99.4 ± 0.6% at 5 years, 97.8 ± 1.7% at 10 and 15 years, and 63.9 ± 14.5% at 20 years. CONCLUSIONS: Patients aged < 60 years undergoing aortic valve replacement with a high mechanical valve implantation rate had favorable long-term outcomes.


Asunto(s)
Válvula Aórtica , Implantación de Prótesis de Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Humanos , Masculino , Persona de Mediana Edad , Femenino , Implantación de Prótesis de Válvulas Cardíacas/métodos , Válvula Aórtica/cirugía , Adulto , Bioprótesis , Estudios Retrospectivos , Complicaciones Posoperatorias/epidemiología , Japón/epidemiología , Estudios de Seguimiento , Resultado del Tratamiento , Tasa de Supervivencia/tendencias , Factores de Edad , Factores de Tiempo , Mortalidad Hospitalaria
14.
J Cardiothorac Surg ; 19(1): 281, 2024 May 07.
Artículo en Inglés | MEDLINE | ID: mdl-38715080

RESUMEN

Injury to coronary arteries during mitral surgery is a rare but life-threatening procedural complication, an anomalous origin and course of the left circumflex artery (LCx) increase this risk. Recognizing the anomaly by the characteristic angiographic pattern and identifying its relationship with the surrounding anatomical structure using imaging techniques, mainly transesophageal echocardiography (TOE) or coronary computed tomography angiography (CCTA), is of crucial importance in setting up the best surgical strategy. We report a case of anomalous origin of a circumflex artery (LCx) from the proximal portion of the right coronary artery (RCA) with a pathway running retroaortically through the mitro-aortic space. An integrated diagnostic approach using a multidisciplinary team with a cardiologist and an imaging radiologist allowed us to decide the surgical strategy. We successfully performed a mitral valvular repair using a minimally invasive minithoracotomic approach and implanting a complete semirigid ring.


Asunto(s)
Válvula Aórtica , Anomalías de los Vasos Coronarios , Ecocardiografía Transesofágica , Válvula Mitral , Humanos , Válvula Mitral/cirugía , Válvula Mitral/diagnóstico por imagen , Válvula Mitral/anomalías , Válvula Aórtica/cirugía , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/anomalías , Anomalías de los Vasos Coronarios/cirugía , Anomalías de los Vasos Coronarios/diagnóstico por imagen , Angiografía Coronaria , Angiografía por Tomografía Computarizada , Masculino , Insuficiencia de la Válvula Mitral/cirugía , Insuficiencia de la Válvula Mitral/diagnóstico por imagen , Femenino , Vasos Coronarios/cirugía , Vasos Coronarios/diagnóstico por imagen
15.
Clin Interv Aging ; 19: 695-703, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38711477

RESUMEN

Purpose: In mixed aortic valve disease (MAVD), the results of transcatheter aortic valve replacement (TAVR) are conflicting. There is limited data on the outcomes of TAVR in patients with bicuspid aortic valve (BAV) and MAVD. The objective of this study is to compare outcomes after TAVR in BAV patients with MAVD and predominant aortic stenosis (PAS). Patients and Methods: Patients with BAV who underwent TAVR between January 2016 and April 2023 were included. The primary outcome was device success. The secondary endpoints were periprocedural mortality and other complications as defined by the Valve Academic Research Consortium-3 (VARC-3). Propensity score matching was used to minimize potential confounding. Results: A total of 262 patients were included in this study, 83 of whom had MAVD. The median age was 72 years, and 55.7% were male. The baseline comorbidity risk files were comparable between the two groups. Patients with MAVD had more mitral regurgitation, tricuspid regurgitation and pulmonary hypertension, larger annular and left ventricular outflow tract dimensions, and more severe calcification than PAS. In the unmatched population, MAVD patients had similar device success rate (69.9% vs 79.9%, P=0.075) and 30-day mortality (3.6% vs 3.4%, P=1) compared to PAS. Propensity score matching resulted in 66 patient pairs. Device success rate were still comparable in the matched population. Other clinical outcomes, including stroke, bleeding (type 2-4), major vascular complications, acute kidney injury (stage 2-4) and permanent pacemaker implantation, were comparable between the two groups. Multivariable logistic regression analysis did not show MAVD to be an independent negative predictor of device success. At one year, survival was similar between patients with MAVD and those with PAS. Conclusion: For the bicuspid valve, patients with MAVD had a more challenging anatomy. MAVD patients associated with comparable 30-day clinical outcomes after TAVR compared to PAS patients in patients with BAV.


Asunto(s)
Estenosis de la Válvula Aórtica , Enfermedad de la Válvula Aórtica Bicúspide , Complicaciones Posoperatorias , Puntaje de Propensión , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Masculino , Femenino , Estenosis de la Válvula Aórtica/cirugía , Anciano , Enfermedad de la Válvula Aórtica Bicúspide/cirugía , Anciano de 80 o más Años , Complicaciones Posoperatorias/epidemiología , Estudios Retrospectivos , Resultado del Tratamiento , Válvula Aórtica/cirugía , Válvula Aórtica/anomalías , Persona de Mediana Edad , Factores de Riesgo , Enfermedades de las Válvulas Cardíacas/cirugía
17.
J Am Heart Assoc ; 13(9): e033846, 2024 May 07.
Artículo en Inglés | MEDLINE | ID: mdl-38639328

RESUMEN

BACKGROUND: Next-day discharge (NDD) outcomes following uncomplicated self-expanding transcatheter aortic valve replacement have not been studied. Here, we compare readmission rates and clinical outcomes in NDD versus non-NDD transcatheter aortic valve replacement with Evolut. METHODS AND RESULTS: Society of Thoracic Surgeons/American College of Cardiology TVT (Transcatheter Valve Therapy) Registry patients (n=29 597) undergoing elective transcatheter aortic valve replacement with self-expanding supra-annular valves (Evolut R, PRO, and PRO+) from July 2019 to June 2021 were stratified by postprocedure length of stay: ≤1 day (NDD) versus >1 day (non-NDD). Propensity score matching was used to compare risk adjusted 30-day readmission rates and 1-year outcomes in NDD versus non-NDD, and multivariable regression to determine predictors of NDD and readmission. Between the first and last calendar quarter, the rate of NDD increased from 45.4% to 62.1% and median length of stay decreased from 2 days to 1. Propensity score matching produced relatively well-matched NDD and non-NDD cohorts (n=10 549 each). After matching, NDD was associated with lower 30-day readmission rates (6.3% versus 8.4%; P<0.001) and 1-year adverse outcomes (death, 7.0% versus 9.3%; life threatening/major bleeding, 1.6% versus 3.4%; new permanent pacemaker implantation/implantable cardioverter-defibrillator, 3.6 versus 11.0%; [all P<0.001]). Predictors of NDD included non-Hispanic ethnicity, preexisting permanent pacemaker implantation/implantable cardioverter-defibrillator, and previous surgical aortic valve replacement. CONCLUSIONS: Most patients undergoing uncomplicated self-expanding Evolut transcatheter aortic valve replacement are discharged the next day. This study found that NDD can be predicted from baseline patient characteristics and was associated with favorable 30-day and 1-year outcomes, including low rates of permanent pacemaker implantation and readmission.


Asunto(s)
Estenosis de la Válvula Aórtica , Alta del Paciente , Readmisión del Paciente , Puntaje de Propensión , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/tendencias , Readmisión del Paciente/estadística & datos numéricos , Readmisión del Paciente/tendencias , Masculino , Femenino , Anciano de 80 o más Años , Estenosis de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/mortalidad , Anciano , Alta del Paciente/tendencias , Sistema de Registros , Tiempo de Internación/estadística & datos numéricos , Tiempo de Internación/tendencias , Factores de Tiempo , Prótesis Valvulares Cardíacas , Complicaciones Posoperatorias/epidemiología , Resultado del Tratamiento , Estados Unidos/epidemiología , Factores de Riesgo , Válvula Aórtica/cirugía , Estudios Retrospectivos , Diseño de Prótesis , Medición de Riesgo
19.
Eur J Cardiothorac Surg ; 65(4)2024 Mar 29.
Artículo en Inglés | MEDLINE | ID: mdl-38608189

RESUMEN

OBJECTIVES: Repair of the bicuspid aortic valve (BAV) has evolved in the past 25 years. The aim of this study was to review and analyse the long-term durability of isolated BAV repair with particular focus on commissural orientation (CO). METHODS: All patients who underwent BAV repair for severe aortic regurgitation between October 1998 and December 2022 were included. The study group consists of all patients operated after 2009, i.e. since CO modification. The control group includes patients who were operated before 2009. CO was classified as symmetric, asymmetric and very asymmetric. RESULTS: Overall, 594 adult patients (93% male; mean age 42 years) were included. At 15 years, survival was 94.8% [standard deviation (SD): 2.2]; freedom from reoperation was 86.8% (SD: 2.3). Freedom from aortic insufficiency ≥II was 70.8% (SD: 4.7) at 15 years. Modification of CO by sinus plication was performed in 200 (33.7%) instances. Using competing risks analysis, the absence of effective height measurement (P = 0.018), very asymmetric CO (P = 0.028), the presence of calcification (P < 0.001), the use of pericardial patch (P < 0.001), the use of subcommissural sutures (P < 0.001) and preoperative endocarditis (P = 0.005) were identified as independent predictors for reoperation. Follow-up was 97% complete (4228 patient-years); mean follow-up was 7 years (SD: 5). CONCLUSIONS: Isolated BAV repair leads to good survival and durability in all morphologic types if cusp repair is guided by effective height, suture annuloplasty is performed, and CO is modified using sinus plication in asymmetrical valves. Very asymmetrical valves may should be treated with a lower threshold for replacement.


Asunto(s)
Insuficiencia de la Válvula Aórtica , Válvula Aórtica , Enfermedad de la Válvula Aórtica Bicúspide , Humanos , Masculino , Enfermedad de la Válvula Aórtica Bicúspide/cirugía , Válvula Aórtica/cirugía , Válvula Aórtica/anomalías , Adulto , Femenino , Insuficiencia de la Válvula Aórtica/cirugía , Persona de Mediana Edad , Estudios Retrospectivos , Resultado del Tratamiento , Reoperación/estadística & datos numéricos , Enfermedades de las Válvulas Cardíacas/cirugía , Adulto Joven , Estudios de Seguimiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA